top of page

Branch Circuit Monitoring

ostrichfeathernew.png

INTRODUCTION

As part of its ongoing commitment to deliver industry leading power metering, monitoring and power quality solutions, MPL Technology Group Limited offers a truly scalable and modular approach to address multi circuit power and energy management suitable for both AC and DC installations.

This proven technology is widely deployed across a broad range of industries and market sectors which include, but is not limited to, the Enterprise, Data Centre, Telecoms, Industrial/Manufacturing and Education sectors.

The solution supports the ability to offer a holistic view of the client’s estate, from building point of entry through to an individual payload.

 

THE DELIVERABLE
 

A compact and modular monitoring solution, which will

report on all monitored single and three phase circuits,

delivering centralised reporting of Voltage, Current, kVA, kW,

kWh, PF, imbalances, alarms and the option of breaker status. This truly ‘building block’ approach to power and energy monitoring brings together a scalable configuration utilising a Voltage acquisition module (for the entire system), multiple Current acquisition modules to measure consumption, combined with a wide portfolio of sensors to measure load currents.

 

At the heart of the system, is the MPL NGEN-GW32BCM Gateway, which centralises data collection and offers real time/historical reporting, alarming and alerting. The solution range is pre-configured into IP65 rated metal enclosures. The standard range of five enclosures will offer up to 72 single phase circuits/24 three phase circuits. The units can be configured with additional modules if required. The enclosures simplify the installation in legacy environments and are factory pre-wired and tested utilising the scalable Digiware modules.

MPL Individual Circuit Monitoring Page 1

CURRENT SENSORS

The smart Current sensors measure the load currents of an electrical circuit and send the data to the Current modules via an RJ12 plug and play output. The sensors are available in three versions, namely Solid Current Sensors (to 2000A), Split Core Current Sensors (to 600A) and Flexible Current Sensors (to 6000A).

The Split and Flexible Sensors are particularly useful

in legacy environments where non-invasive installation may avoid unwanted power downtime. The following table highlights the standard range of sensors available by sensor type and cable aperture size.

ADDITIONAL FUNCTIONALITY OPTIONS

  • For Telecoms applications, DC versions of the enclosures are available and suitable for both 24VDC and 48VDC nominal voltages

  • Digital and analogue input/output modules can be added to monitor third party devices and collect data from analogue sensors i.e. temperature, humidity and pressure (0/4-20mA)

  • MID certified measurement solutions can be integrated for applications where there is a direct correlation between measured data and an invoice

  • The enclosure range is also available with enhanced
    Power Quality monitoring and analysis including predictive power, over currents, individual harmonics and P, Q, S and PF per phase.

BCMSOLUTIONBENEFITS.PNG

AC CURRENT SENSORS

The smart Current sensors measure the load currents of an electrical circuit and send the data to the Current modules via an RJ12 plug and play output. The sensors are available in three versions, namely Solid Current Sensors (to 2000A), Split Core Current Sensors (to 600A) and Flexible Current Sensors (to 6000A).

The Split and Flexible Sensors are particularly useful in legacy environments where non-invasive installation may avoid unwanted power downtime. The following table highlights the standard range of sensors available by sensor type and cable aperture size.

MPL Circuit Monitoring Chart 2.jpg

DC CURRENT SENSORS

The DC current sensors measure DC load currents of an electrical installation and transmit information to the current modules via an RJ12 to Molex cable (4 pin connector).

The range comprises solid core and split sensors ranging from 50 to 5000A in various sizes allowing them to be used

in new or legacy electrical installations.

These open-loop hall effect sensors are available in two frame sizes per sensor type to accommodate a wide range of current ratings and cable sizes.

MPL Circuit Monitoring Chart 3.jpg
MPL Circuit Monitoring Solid:Split.jpg

Solid and Split Core DC Current Sensors

VISUALISATION

The NGEN Gateway centralises data collection and displays the real time and historical reporting via the embedded NGEN software. In addition to the reporting capabilities, NGEN will provide real time alerting and alarming against pre-defined thresholds defined by the client.

TAILOREDDASH.png
bottom of page